Effectively filters, among others, iron, manganese and limescale
Large surface area and porous ion exchange resin
Cleaning and operating principles:
Dense mechanical filter filters solid particles down to 5 µm
By ion exchange, iron, manganese and limescale, among others, are removed from the water. The pH value of the water has no effect on the cleaning efficiency
Filters from the water:
Iron 2 mg/l (recommended), maximum 4 mg/l
Manganese 0.3 mg/l (recommended), maximum 0.5 mg/l
Limescale
Lead and copper
Solid particles
Organic matter. Maximum recommended organic matter COD 10 mg/l.
Technical specifications:
Filter capacity approx. 55,000 litres when the combined amount of iron and manganese is 1000 µg/l. Other water properties may affect the actual filter capacity
Operating temperature 2–30 °C
Recommended water flow rate approx. 5 litres per minute
pH value has no effect on capacity or cleaning efficiency
In winter, if temperatures drop below 2 °C, to prevent frost damage, the water lines are shut off and the in-line filter housings are emptied. The filters are stored warm and dry if they are to be reused.