Acidic Water Neutralization Filter
Suitable for raising the pH level of water.
The operation is based on natural water alkalization. The redesigned, Finnish-made filter cartridge contains domestic calcium. Low pH levels can cause corrosion in copper pipes, for example.
Technical Specifications:
Indicative pH increase at different flow rates (liters per minute):
- 5 lpm = +1
- 10 lpm = +0.7
- 15 lpm = +0.6
Connecting multiple filters in series can increase the pH rise relative to the flow rate.
Filter Capacity:
The capacity depends on the water’s properties and the initial pH value. At pH 6, approximately 60,000 liters. Water properties affect practical capacity; generally, lower pH reduces capacity, while higher pH increases it.
Recommended Use:
For pH levels between 5.0 and 6.9.
Filter Activation:
The calcium-containing filter must be flushed with plenty of water during initial setup. Flushing should be repeated several times.*
*Note: Follow the additional instructions provided with the filter cartridge.